{"id":2123,"date":"2023-09-03T12:33:29","date_gmt":"2023-09-03T12:33:29","guid":{"rendered":"https:\/\/adityaelectric.com\/?post_type=product&#038;p=2123"},"modified":"2026-03-02T08:11:58","modified_gmt":"2026-03-02T08:11:58","slug":"apfc-panel","status":"publish","type":"product","link":"https:\/\/adityaelectric.com\/index.php\/product\/apfc-panel\/","title":{"rendered":"APFC Panel"},"content":{"rendered":"<h3><strong>Salient Features<\/strong><\/h3>\n<ul>\n<li>Maintains system power factor close to unity (0.99 lag) automatically<\/li>\n<li>Microprocessor \/ PLC-based intelligent APFC relay for accurate control<\/li>\n<li>Rated voltage: <strong>415 V, 3-phase, 50 Hz<\/strong><\/li>\n<li><strong>Rating:<\/strong> Up to 1000 KVAR (or as required)<\/li>\n<li>Heavy-duty capacitor banks (APP \/ MPP \/ Detuned type)<\/li>\n<li>Equipped with reactors for <strong>harmonic filtration<\/strong> (if required)<\/li>\n<li>Modular design with easily serviceable construction<\/li>\n<li>Floor-mounting \/ wall-mounting type panels available<\/li>\n<\/ul>\n<h3><strong>Constructional Details<\/strong><\/h3>\n<ul>\n<li><strong>Enclosure:<\/strong> Fabricated from high-quality CRCA sheet steel, powder-coated with epoxy-polyester paint<\/li>\n<li><strong>Bus Bars:<\/strong> High-conductivity aluminum or copper, fully insulated and color coded<\/li>\n<li><strong>Cooling:<\/strong> Natural or forced-air cooling with adequate ventilation<\/li>\n<li><strong>Switching Devices:<\/strong> Capacitor contactors \/ thyristor switches for step control<\/li>\n<li><strong>Protection:<\/strong> Over-voltage, under-voltage, and short-circuit protection<\/li>\n<\/ul>\n<h3><strong>Functional Description<\/strong><\/h3>\n<ul>\n<li>Continuously monitors system power factor and automatically switches appropriate capacitor steps through APFC relay logic.<\/li>\n<li>Reduces reactive power demand and prevents low power factor penalties.<\/li>\n<li>Improves voltage regulation, system stability, and overall efficiency.<\/li>\n<\/ul>\n<h3><strong>Testing &amp; Quality<\/strong><\/h3>\n<ul>\n<li>Routine and type-tested as per IS \/ IEC standards.<\/li>\n<li>Each panel undergoes dielectric, insulation resistance, and functional testing before dispatch.<\/li>\n<\/ul>\n<h3><strong>Applications<\/strong><\/h3>\n<ul>\n<li>Industrial Loads<\/li>\n<li>Commercial Complexes<\/li>\n<li>Hospitals, Hotels, and Shopping Malls<\/li>\n<li>Substations and Utility Networks<\/li>\n<li>Renewable Energy Plants (Solar \/ Wind)<\/li>\n<\/ul>\n<h3><strong>Optional Features<\/strong><\/h3>\n<ul>\n<li>Detuned \/ Tuned Reactors for Harmonic Mitigation<\/li>\n<li>Real-time Power Factor Monitoring with Digital Display<\/li>\n<li>IoT-based Power Factor &amp; Energy Monitoring System<\/li>\n<li>Auto\/Manual Operation Mode<\/li>\n<li>Remote control via SCADA \/ BMS<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p style=\"text-align: justify;\"><span lang=\"EN-IN\">Our <strong>Automatic Power Factor Control (APFC) Panels<\/strong> are designed to maintain the desired power factor automatically by switching capacitor banks on or off according to the reactive power requirement of the system. This ensures optimum utilization of electrical energy, reduces penalties from utilities, and improves overall system efficiency.<\/span><\/p>\n<p style=\"text-align: justify;\"><span lang=\"EN-IN\"><br \/>\nThese panels are engineered in compliance with <strong>IS 8623 \/ IEC 61439<\/strong> standards for maximum safety, reliability, and operational efficiency.<\/span><\/p>\n","protected":false},"featured_media":2880,"comment_status":"open","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[40],"product_tag":[],"class_list":{"0":"post-2123","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-apfc-panel","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"uagb_featured_image_src":{"full":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2023\/09\/6-1.png",1344,768,false],"thumbnail":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2023\/09\/6-1-150x150.png",150,150,true],"medium":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2023\/09\/6-1-300x171.png",300,171,true],"medium_large":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2023\/09\/6-1-768x439.png",768,439,true],"large":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2023\/09\/6-1-1024x585.png",1024,585,true],"1536x1536":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2023\/09\/6-1.png",1344,768,false],"2048x2048":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2023\/09\/6-1.png",1344,768,false],"woocommerce_thumbnail":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2023\/09\/6-1-300x300.png",300,300,true],"woocommerce_single":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2023\/09\/6-1-600x343.png",600,343,true],"woocommerce_gallery_thumbnail":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2023\/09\/6-1-100x100.png",100,100,true]},"uagb_author_info":{"display_name":"dgtechinfotech","author_link":"https:\/\/adityaelectric.com\/index.php\/author\/"},"uagb_comment_info":2,"uagb_excerpt":"Our Automatic Power Factor Control (APFC) Panels are designed to maintain the desired power factor automatically by switching capacitor banks on or off according to the reactive power requirement of the system. This ensures optimum utilization of electrical energy, reduces penalties from utilities, and improves overall system efficiency. These panels are engineered in compliance with&hellip;","_links":{"self":[{"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/product\/2123","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/comments?post=2123"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/media\/2880"}],"wp:attachment":[{"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/media?parent=2123"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=2123"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=2123"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=2123"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}