{"id":2119,"date":"2023-09-03T12:14:44","date_gmt":"2023-09-03T12:14:44","guid":{"rendered":"https:\/\/adityaelectric.com\/?post_type=product&#038;p=2119"},"modified":"2026-03-29T21:26:46","modified_gmt":"2026-03-29T21:26:46","slug":"pdb-panel","status":"publish","type":"product","link":"https:\/\/adityaelectric.com\/index.php\/product\/pdb-panel\/","title":{"rendered":"PDB PANEL"},"content":{"rendered":"<h3><strong>Salient Features<\/strong><\/h3>\n<ul>\n<li>Rated up to <strong>415 V, 50 Hz, 3-phase, 4-wire system<\/strong><\/li>\n<li><strong>Current Rating:<\/strong> Up to 4000 A<\/li>\n<li><strong>Short Circuit Withstand:<\/strong> Up to 65 kA for 1 sec<\/li>\n<li><strong>Ingress Protection:<\/strong> IP-42 \/ IP-52 \/ IP-65 (as required)<\/li>\n<li>Modular, compact, and robust design<\/li>\n<li>Easy accessibility for maintenance and cable termination<\/li>\n<li>Suitable for indoor or outdoor installation<\/li>\n<\/ul>\n<h3><strong>\u00a0<\/strong><strong>Constructional Highlights<\/strong><\/h3>\n<ul>\n<li><strong>Enclosure:<\/strong> Fabricated from high-quality CRCA sheet steel, powder-coated with epoxy-polyester finish for corrosion resistance.<\/li>\n<li><strong>Bus Bars:<\/strong> High-conductivity electrolytic copper or aluminum, fully insulated and color-coded for phase identification.<\/li>\n<li><strong>Compartmentalization:<\/strong> Segregated sections for incomer, bus bar, and outgoing feeders to enhance safety and serviceability.<\/li>\n<li><strong>Cable Entry:<\/strong> Top or bottom cable entry provision as per site requirement.<\/li>\n<li><strong>Mounting:<\/strong> Free-standing, wall-mounted, or pedestal-mounted type.<\/li>\n<\/ul>\n<h3><strong>Electrical Components<\/strong><\/h3>\n<ul>\n<li><strong>Incomer:<\/strong> ACB \/ MCCB \/ SFU \/ Isolator with or without metering<\/li>\n<li><strong>Outgoings:<\/strong> MCCBs \/ MCBs \/ Contactors \/ Switch Fuses<\/li>\n<li><strong>Metering:<\/strong> Digital multifunction meters for voltage, current, kW, PF, frequency, and energy<\/li>\n<li><strong>Indication:<\/strong> LED indication lamps and pushbuttons<\/li>\n<li><strong>Protection:<\/strong> Overload, short-circuit, and earth fault protection<\/li>\n<\/ul>\n<h3><strong>Testing &amp; Quality<\/strong><\/h3>\n<p>Every LT panel is <strong>routinely tested<\/strong> as per IS\/IEC standards for:<\/p>\n<ul>\n<li>High-voltage dielectric test<\/li>\n<li>Insulation resistance test<\/li>\n<li>Functional operation test<\/li>\n<li>Visual and mechanical inspection<\/li>\n<li>All panels undergo thorough quality checks to ensure performance, reliability, and compliance with the client\u2019s technical specifications.<\/li>\n<\/ul>\n<h3><strong>Applications<\/strong><\/h3>\n<ul>\n<li>Industrial Plants and Process Industries<\/li>\n<li>Commercial Buildings and Complexes<\/li>\n<li>Power Utilities and Substations<\/li>\n<li>Infrastructure and Public Facilities<\/li>\n<li>Renewable Energy Projects (Solar \/ Wind)<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li style=\"text-align: justify;\">Distributes electrical power from the main source (like PCC or transformer) to various sub-loads or machines.<\/li>\n<li style=\"text-align: justify;\">Equipped with MCCBs, MCBs, or switch fuses for outgoing feeders.<\/li>\n<li style=\"text-align: justify;\">Provides protection against overload and short-circuit faults.<\/li>\n<li style=\"text-align: justify;\">Used in industries, commercial buildings, and utilities for secondary power distribution<\/li>\n<\/ul>\n","protected":false},"featured_media":2821,"comment_status":"open","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[53],"product_tag":[54],"class_list":{"0":"post-2119","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-pdb-panel","7":"product_tag-pdbpanel","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"uagb_featured_image_src":{"full":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2026\/02\/4.jpeg",1280,960,false],"thumbnail":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2026\/02\/4-150x150.jpeg",150,150,true],"medium":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2026\/02\/4-300x225.jpeg",300,225,true],"medium_large":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2026\/02\/4-768x576.jpeg",768,576,true],"large":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2026\/02\/4-1024x768.jpeg",1024,768,true],"1536x1536":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2026\/02\/4.jpeg",1280,960,false],"2048x2048":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2026\/02\/4.jpeg",1280,960,false],"woocommerce_thumbnail":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2026\/02\/4-300x300.jpeg",300,300,true],"woocommerce_single":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2026\/02\/4-600x450.jpeg",600,450,true],"woocommerce_gallery_thumbnail":["https:\/\/adityaelectric.com\/wp-content\/uploads\/2026\/02\/4-100x100.jpeg",100,100,true]},"uagb_author_info":{"display_name":"dgtechinfotech","author_link":"https:\/\/adityaelectric.com\/index.php\/author\/"},"uagb_comment_info":5,"uagb_excerpt":"Distributes electrical power from the main source (like PCC or transformer) to various sub-loads or machines. Equipped with MCCBs, MCBs, or switch fuses for outgoing feeders. Provides protection against overload and short-circuit faults. Used in industries, commercial buildings, and utilities for secondary power distribution","_links":{"self":[{"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/product\/2119","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/comments?post=2119"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/media\/2821"}],"wp:attachment":[{"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/media?parent=2119"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=2119"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=2119"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/adityaelectric.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=2119"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}